DEMO Synthetic data for South Carolina corridors. Plates beginning with DEMO are fabricated for stakeholder previews. Toggle demo mode off to dismiss.
Operator Console
System Disabled
← Back to Violations
AUTOMATED SPEED ENFORCEMENT
Calculation Audit Trail
Violation Reference V-2026-004797
Issued 2026-10-14 04:02:43
Status Issued
Corridor
Corridor Name I-185 Greenville
Gantry A Greenville Gantry
Gantry B Mauldin Gantry
Surveyed Distance 6.5 mi
Enforcement
Posted Limit 60 mph
Active Threshold 70 mph (posted + 10)
Subject Vehicle
Plate (Synthetic) DEMO-9587
Vehicle Class Sedan
Read 1 — Gantry A
Gantry Greenville Gantry
Location I-185 northbound near Greenville
Coordinates 34.8000, -82.4000
Timestamp 2026-11-01T04:32:29.587
Plate Read Confidence 88.2%
Read 2 — Gantry B
Gantry Mauldin Gantry
Location I-185 northbound near Mauldin
Coordinates 34.7800, -82.3100
Timestamp 2026-11-01T04:37:16.592
Plate Read Confidence 98.4%
Time-Over-Distance Calculation
Surveyed Distance 6.5 mi
Elapsed Time 04:47.005 (MM:SS.mmm)
Calculated Avg Speed 81.5 mph
Posted Limit Delta +21.5 mph
Threshold Check
Active Threshold 70 mph
Result EXCEEDED
Magnitude over Threshold +11.5 mph
Edge Case Checks
Inferred Stop Between Gantries None
Plate Read Confidence A ≥ 95% FAIL (88.2%)
Plate Read Confidence B ≥ 95% PASS (98.4%)
Timestamp Anomaly Check PASS
Confidence Score
93.3 / 100

Methodology: confidence score is the mean of the two plate read confidences, adjusted for any failed edge case check. Reads below 95% trigger a flag for review. Stop-time and timestamp-anomaly failures suppress automatic issuance.

Payment
Status Unpaid
Date Paid not yet paid
Payment Method Not yet paid
Fine Amount $300.00
Reviewer
Reviewer Pending review